Glen Dimplex Home Appliances Ltd Ventilation Hood CHIM101 User Manual

Cooker Hood  
CHIM60  
CHIM70  
CHIM90  
CHIM101  
CHIM110  
Installation & User’s instructions  
 
167.5  
250  
A
Z
B
E
206  
167  
F
C
D
230  
230  
Fig.1  
Fig.3  
G
A
B
E
Z
Z
F
Y
C
D
490  
Fig.2  
Fig.4  
 
3
Your new Belling Cooker Hood  
Dear Customer  
These instructions are designed to help you know your new cooker hood quickly and to achieve  
the best possible results.  
It is most important that this instruction book should be retained with the appliance for future  
reference. Should the appliance be sold or transferred to another owner, or should you move  
house and leave the appliance, always ensure that the book is supplied with the appliance in  
order that the new owner can be acquainted with the functioning of the appliance and the relevant  
warnings. Please ensure that you have read the whole instruction book before using the  
appliance and that you follow the recommendations.  
Warnings  
These warnings are provided in the interest of safety. Please read carefully before  
installing or using the appliance.  
1.  
2.  
Keep children away from the product.  
Any installation work must be undertaken by a competent person and installed in  
accordance with the current IEE regulations.  
3.  
4.  
It is dangerous to alter the specification or modify the product in any way.  
If this appliance is to be connected to a ventilation system, it should not be joined  
with a ventilation system from any other appliance.  
5. The product should be serviced by an authorised Belling service engineer and  
only genuine Belling spare parts should be used.  
General information  
This instruction book applies to the following models:  
CHIM60  
CHIM70  
CHIM90  
CHIM101  
CHIM110  
This cooker hood is guaranteed and will give lasting service. The guarantee is only  
applicable if the hood has been installed in accordance with these instructions.  
The cooker hood has been designed for use fixed directly onto a wall. The hood can be  
used to extract odours to the outside or to recirculate the air within the kitchen after  
passing through a cleansing charcoal filter. Charcoal filters are supplied as an optional  
extra, please phone Belling Spares department on 0844 815 3745 and quote part number  
CHT28.  
The hood is convertible to either function.  
Belling disclaims any liability for any damage or injury caused as a result of not following  
the installation & user instructions.  
4
 
Warning: This hood is designed for domestic use only.  
When used in the extraction mode the cooker hood ducting must not be connected to a  
flue which is used for exhausting fumes from appliances supplied with energy other than  
electric, such as a central heating flue or a water heater flue.  
If the room where the cooker hood is to be used contains a fuel burning appliance such as  
a central heating boiler, then its flue must be of the room sealed or balanced flue type. If  
other types of flue or appliances are fitted, ensure there is adequate ventilation in the  
room.  
All installations must comply with local authority requirements for the discharge of exhaust  
air.  
Positioning  
When installed above a cooking appliance the distance between the surface of the  
appliance hotplate and the lower grill of the hood must not be less than 65cm (25½”).  
This appliance is suitable for ceiling heights of approximately 225cm (7’5”) and 262cm  
(8’7”) depending on the installation. If you have a ceiling greater than this height please  
ring our spares department on 0844 815 3745 for the tall ceiling kit (see Optional Extras).  
Do not fit above a cooker with a high level grill.  
The distance between adjoining wall cabinets and the worktop must not be less than  
40cm (15¾”).  
If the cooker hood is installed for use above a gas appliance then the provision for  
ventilation must be in accordance with the Gas Safety (Installation and Use) Regulations  
and the relevant building regulations.  
Warning: The fan motor of this cooker hood incorporates a thermal cut-out which will  
operate if the cooker hood is installed below the minimum recommended height or the  
motor overheats. If the cut-out operates. Switch off the cooker hood and allow the motor  
to cool, the cutout will then reset itself.  
Unpacking  
Care should be taken when unpacking the cooker hood to ensure that the outlet flange,  
screws and wall plugs, literature pack etc. are retained with the hood.  
- Components  
The hood consists of :  
1 hood body complete with controls and lights  
1 complete telescopic flue  
1 connecting flange Y.  
1 bracket Z to fix the flue unit to the wall  
1 bag containing screws and documents  
5
 
Installation Instructions  
Wall fitting  
The cooker hood may be fitted to any rigid vertical surface. All the fittings supplied are  
to be found in the polythene bag.  
Important: Before installation, check the wall to which the cooker hood is to be fitted, for  
electric cables, water or gas pipes before drilling. If it is necessary to fix the hood to a  
hollow construction, plaster or partition structure, suitable fittings (not included) must be  
used.  
Mounting the hood to the wall  
Drill 8 holes (B, C, D) respecting the distances indicated (Fig. 3) and the holes A using  
the bracket Z as template. Fix the bracket Z to the wall (Fig. 3).  
Hang the hood on the wall using the holes C (Fig. 3). After having levelled the appliance  
finally secure the hood to the wall using the holes D.  
Internal Exhausting  
Screw the connecting flange Y to the exhaust fan unit on the hood body (Fig. 2). Insert the  
upper flue E into the lower flue F with the slots facing upwards. Pull out the upper flue as  
far as the bracket Z and fix it with the screws provided.  
Charcoal filters are used to purify the air which will be recycled into the room. The filters  
cannot be washed or regenerated and must be replaced every 4 months.  
The charcoal filters are supplied as an optional extra, please phone Belling Spares  
department on 0844 815 3745 and quote part number CHT28.  
Saturation of the activated charcoal depends on more or less extensive use of the hood,  
the type of kitchen and the regularity of cleaning the grease filter. The air is recycled into  
the room through the slots in the flue E.  
External Exhausting  
Fix the connecting flange Y (Fig. 2). By means of a connection pipe of 120 mm internal  
diameter, connect the flange Y to the outlet opening. Insert the upper flue E into the lower  
flue F with the slots facing downwards (Fig. 2).  
Fix the lower flue to the wall using the previously drilled holes B (Fig. 3). Pull out the  
upper flue as far as the bracket Z and fix it with the screws provided.  
Electrical Connection  
Before connecting to the mains supply ensure that the voltage is as stated on the rating  
plate inside the cooker hood.  
Warning: This appliance is fully insulated and must not be earthed.  
The appliance comes with a 2 core mains cable and should be permanently connected to  
the electricity supply via a double pole switched fused spur outlet with a minimum contact  
clearance of 3mm in both poles.  
Installation must comply with the latest IEE regulations and must be carried out by a  
competent person.  
The cooker hood must be protected by a 3-amp fuse.  
6
 
Use and Maintenance  
It is advisable to switch the cooker hood on a few minutes before cooking starts and that it  
be left on for about 15 minutes after cooking is completed to exhaust all the odours.  
On the front of the hood there are:  
1.  
2.  
3.  
4.  
Cooker hood On indicator light  
On/off switch  
3 buttons to adjust the motor speed  
An on/off switch for the light.  
Good functioning of the hood depends on the regularity with which maintenance  
operations are carried out, in particular the anti-grease filters and the activated charcoal  
filter. The anti-grease filters have the function of holding back grease  
particles suspended in the air, and are thus subject to clogging with time depending on the  
frequency of use of the appliance.  
Clean the filters every 2 months by carrying out the following operations:  
- Remove the filters from the hood and wash them with warm soapy water.  
- Rinse in lukewarm water and leave them to dry.  
- The filters may also be washed in the dishwasher.  
The aluminium panels may be subject to colour alterations after washing. This is natural  
over time and will not affect the performance of the appliance.  
If filters are not cleaned regularly, there may be a risk of them catching fire.  
Frequently clean off any deposits on the fan and other surfaces, using warm soapy water.  
Replacement of the standard lamp  
WARNING!! DISCONNECT FROM MAINS BEFORE CHANGING LAMP  
Note: The bulb is not covered by the guarantee as it is a consumable item.  
Lamps are available from our spares department, please ring 0844 815 3745 and quote  
part no.CHT15  
1.  
2.  
3.  
4.  
Switch off the light on the top of the appliance.  
Release the grease filters to gain access to the bulbs.  
Replace bulb (40W SES).  
Refit filters.  
Replacement of the Halogen Lamp  
WARNING!! DISCONNECT FROM MAINS BEFORE CHANGING LAMP  
Note: The bulb is not covered by the guarantee as it is a consumable item.  
Lamps are available from our spares department, please ring 0844 815 3745 and quote  
part no.CHT265A  
To replace the halogen lamp, carefully prise off the cover and remove complete with the  
lamp glass.  
Put in the new lamp taking care not to touch the glass with fingers and replace lamp glass  
and cover.  
7
 
Do’s and Don’ts  
Do take extra care when frying  
Do clean grease filters and hood regularly  
Do change charcoal filters regularly  
Don’t leave naked flames under the cooker hood  
Don’t leave frying pans unattended during use as overheated fat may catch fire  
Don’t flambé cook under the cooker hood  
Don’t try to check the filters when the hood is in operation.  
Don’t touch the lamp after prolonged use of the appliance.  
If your cooker hood doesn’t work  
Check the power supply and fuse  
Is the hood switched on?  
Has the hood become too hot and switched itself off?  
If hood is still not working call for service  
This appliance conforms to the following EEC directives  
Low Voltage Directive  
73/23/EEC  
93/68/EEC  
Electromagnetic Compatibility  
89/336/EEC  
92/31/EEC  
93/68/EEC  
8
 
Optional extras  
Please quote the following part number if you require a ducting or tall ceiling kit.  
Filter  
CHT28  
Ducting Kit  
Ducting Kit  
Short  
Long  
CHIM100004 (1m)  
CHIM100004A (3m)  
CHIM110002  
CHIM60001  
Tall ceiling kit Green  
Tall ceiling kit Black (Satin)  
Tall ceiling kit Black (Matt)  
Tall ceiling kit Stainless Steel  
Tall ceiling kit Aluminium  
CHIM110001  
CHIM601002  
CHIM70001  
Calling for Service  
Please contact your retailer in the first instance. If you experience difficulty contact Belling  
Appliances (After Sales Division)  
Remember that you may be charged for the visit (even during the guarantee period) if noth-  
ing is found to be wrong with the appliance, so always check the instructions in case you  
have missed anything.  
Belling Appliances After Sales Division (Service)  
Tel: 0844 815 3746 (all calls will be charged at local rate)  
Before contacting a service agent, please note the following details about your cooker:  
Model Number  
________________________________________________________  
Serial Number  
________________________________________________________  
Date of Purchase  
______________________________________________________  
Also note your Postcode  
________________________________________________________  
In order to provide a complete service history for your cooker please ask the service engi-  
neer to record the appropriate details in the chart below.  
Date  
Nature of Fault  
Parts replaced or repaired  
Authorised stamp or  
signature  
9
 
10  
 
11  
 
Belling Appliances Ltd.  
Stoney Lane, Prescot, Merseyside L35 2XW  
PART No. CHIM110001 Issue 1: 01/2002  
 

Euro Pro Carpet Cleaner S3306H User Manual
Excalibur electronic Games SF34 User Manual
Explorer DVR 8000TM User Manual
Fisher Price Baby Toy V3254 User Manual
Fisher Price Riding Toy T4963 User Manual
Friedrich Air Conditioner CP18 User Manual
Fusion Speaker MS CK602 User Manual
Gefen Portable Generator GTB HD SIGGEN User Manual
GE Range 164D2966P118 User Manual
Global Machinery Company Saw MPS184M User Manual